High side pressure range -14.5 to 800.0 PSIG (-1.0 to 55 bar)
Low side pressure range -14.5 to 800.0 PSIG (-1.0 to 55 bar)
Pressure reading accuracy +/- 1% of reading or +/- 0.5 PSIG (+/- 0.05 bar)
Pressure reading resolution 0.5 PSIG (0.05 bar)
High and low side burst pressure 1500.0 PSIG (103.4 bar)
High side temperature range -58.0 °F to 302 °F (-50 °C to 150°C)
Low side temperature range -58.0 °F to 302 °F (-50 °C to 150°C)
Temperature reading accuracy +/- 0.36 °F (+/- 0.2°C)
Vacuum indication accuracy +/- 10 microns (requires MDXVG accessory)
SH, SC & saturation temperature accuracy +/- 0.5°F (+/- 0.3°C)
Instrument working temperature -4.0 °F to 122°F (-20°C to 50°C)
Instrument working RH range 0% to 100% non-condensing
APO (Automatic Power Off) 10 minutes. Can be disabled by user.
2 valve size (L x H x W) 8.1” x 2.5” x 7.0” (20.5 cm x 6.4 cm x 17.8cm)
2 valve weight 3.0 lb. (1.4 kg)
Display Life using 4 industrial alkaline AA batteries (included) Backlight full ON: 25+ hrs. continuous duty
Display Life using 4 industrial alkaline AA batteries (included) Backlight full OFF: 60+ hrs. continuous duty
Display Life using 4 Rechargeable NiMH AA batteries (not included) Backlight full ON: 20+ hrs. continuous duty from full charge
Display Life using 4 Rechargeable NiMH AA batteries (not included) Backlight full OFF: 50+ hrs. continuous duty from full charge
|