ECA 450 Environmental Analyzer

ECA 450 Environmental Analyzer

Portable Environmental Analyzer for Industrial Applications
  • Measures up to 7 gases simultaneously (minimum O2 and CO), including NOx, SOx and combustibles
  • Sensors are easily replaced or upgraded in the field
  • Rugged suitcase design with large, easy-to-read display
  • Built-in printer for instant traceability and record-keeping

 Description
The ECA 450 is an industrial grade analyzer ideal for professionals concerned about combustion efficiency, environmental compliance, or both. 
Accommodating up to seven sensors, simultaneous measurements and calculated parameters are evaluated to ensure that industrial equipment is
meeting environmental regulations while burning safely and efficiently.
The ECA 450 is designed for on-demand or semi-continuous sampling of industrial furnaces, boilers and other industrial combustion equipment. It 
complies with regulations such as U.S. EPA test methods, EN 50379, CTM-030 and state/local protocols including SCAQMD.
*Note: The ECA 450 calculates CO2 value based upon other measured values during the combustion process. It does not measure CO2 directly.
 Specifications
Measurements:				O2: 0 to 20.9%
					        CO (low-range, H2 compensated): 0 to 4,000 ppm
					        CO (high-range, optional): 4001 to 80,000 ppm
					        NO (optional): 0 to 3500 ppm
					        NO2 (optional): 0 to 500 ppm
					        SO2 (optional): 0 to 4,000 ppm
					        Combustibles (optional): 0 to 5% vol. (application dependent)
					        Stack temperature: -4 to 2400°F (-20 to 1215°C)
					        Primary / ambient air temperature: -4 to 999°F (-20 to 537°C)
					        Draft / differential pressure: 27.7 inH2O (±69 mbar)

Power					        Internal rechargeable battery or via supplied wall adapter

Run Time					8 hours minimum

Size (H x W x D)				13.5 x 18.5 x 9 in. (34.3 x 47.0 x 22.9 cm)

Weight					25 lb. (11.3 kg)

Fuels[1]					Natural gas, coal, oil 2/4/5/6, wood, kerosene, bagasse, propane, LPG, KOKS, LEG, biofuel

Operating Conditions			Analyzer: 32 to 104 °F (0 to 40 °C), 15 to 90% RH (non-condensing), 1 ATM ± 10%
					        Probe tip[2]: 1472 °F (800 °C) maximum, 10 inH2O (25 mbar) maximum draft

Warm-up Time				60 seconds

Memory					1000 locations

Communications				RS-232

Approvals					CE mark

Warranty					1 year (including sensors)

[1] Depending upon combustion equation type – see manual for details
[2] For standard 12 in. probe, P/N 0024-3023
Technical Library   Part Numbers   Accessories & Parts   Gas List