Part Numbers
Product Codes
DCC-SD-NH3 Electrochemical ammonia (NH3) sensor (0 - 500 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires special non-absorbent Teflon lined tubing (sold separately)
DCC-SD-COA Electrochemical 3-year carbon monoxide (CO) sensor (0 - 200 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-C2H4 Electrochemical ethylene (C2H4) sensor (0 - 200 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-EETO Electrochemical ethylene oxide (C2H4O) sensor (0 - 20 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-CH2O Electrochemical formaldehyde (CH2O) sensor (0 - 5 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-EH2 Electrochemical hydrogen (H2) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-HF Electrochemical hydrogen fluoride (HF) sensor (0 - 10 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-H2S Electrochemical 2+ years hydrogen sulphide (H2S) sensor (0 - 50 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-H2SB Electrochemical 5+ years hydrogen sulphide (H2S) sensor (0 - 50 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-NO Electrochemical nitric oxide (NO) sensor (0 - 100 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-SO2 Electrochemical sulphur dioxide (SO2) sensor (0 - 20 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-SR22 Solid state refrigerant (R22) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-SR134A Solid state refrigerant (R134A) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-SR402A Solid state refrigerant (R402A) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-SR404A Solid state refrigerant (R404A) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-SR407C Solid state refrigerant (R407) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-SR410A Solid state refrigerant (R410A) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-SR422D Solid state refrigerant (R422D) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure,requires standard Tygon polymer tubing (sold separately)
DCC-SD-SR438A Solid state refrigerant (R438A) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-SR507A Solid state refrigerant (R507A) sensor (0 - 2,000 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
DCC-SD-STVOC Solid state TVOC sensor (0 - 500 PPM range), LCD display with LED indicators, loud audible alarm, sample draw pump, flow detector with blocked flow alarm, internal adjustable flow meter, one 5A @ 240 VAC SPDT relays, one configurable 4-20 mA output, 24 VAC, water / dust tight enclosure, requires standard Tygon polymer tubing (sold separately)
CET-8000-CMT Standard Tygon polymer clear sample draw tubing, 1/8" ID x 1/4" OD, 15.24 m / 50 ft roll sold separately
CET-8000-CTRL For use with DCC-SD-NH3, Teflon lined, special non-absorbent sample draw tubing, 13/16" ID x 5/16" OD, 5.24 m / 50 ft roll sold separately