LPT-P Digital Car Park Transmitter

LPT-P Digital Car Park Transmitter
For monitoring: Carbon monoxide, Nitrogen dioxide, Methane, Propane, Hydrogen
3 channel, digital (Modbus®) gas detector for enclosed parking facilities
Applications
Parking Facilities, Vehicle Repair Shops, Electric Car Charging Stations, Battery Charging Rooms, and many more...
Key Features
  • 1, 2 or 3 channel operation with internal and/or remote sensor configurations
  • Modbus® RS-485 RTU communication
  • LCD display
  • 24 VDC power
  • 4-conductor daisy chain network wiring
  • Standard water / dust tight, corrosion resistant enclosure (drip proof)
  • IP54 rated with optional splash guard installed.

 Description
The LPT-P is an economical, three channel, digital transmitter that is designed to be part of a gas detection system 
for enclosed parking facilites/parkades and vehicle repair shop applications. It can be configured with a single and/or
dual internal electrochemical Carbon monoxide (CO) and/or Nitrogen dioxide (NO2) sensor and/or one catalytic
combustible ESH-A Remote Sensor.
The LCD display provides at-a-glance gas readings for each channel along with alarm and communication status. 
Navigating the menu can be done unobtrusively with a magnetic wand or by using the internal programming buttons.
The LPT-P is not a standalone gas detection device, it operates on a local area network (LAN) using Modbus® 
RS-485 RTU serial communications with a Controller, a control panel, Direct Digital Control system (DDC) or a Building
Automation System (BAS). The LPT-P does not have an internal alarm or relay.
The LPT-P comes in a standard water / dust tight, corrosion resistant ABS/ polycarbonate enclosure with a hinged, 
secured door. With the optional splash guard installed, the enclosure is IP54 rated and ideal for use in water spray
or wash down applications.
 Specifications
Target Gas

Gas Sensors
Carbon monoxide (CO), Nitrogen dioxide (NO2), Hydrogen (H2), Methane (CH4),
Propane (C3H8)


Mechanical
Enclosure
ABS / Polycarbonate, corrosion resistant Copper coated interior to reduce RF interference IP54 rated with splash guard installed

Weight					363 g / 0.8 lbs

Size					        127 x 127 x 71 mm / 5.0 x 5.0 x 2.8 inches


User Interface
Display
Graphic LCD, white border Magnetic switches to initiate calibration without opening the enclosure


Input/Output
Output Modbus® RS-485 RTU


Electrical
Power Requirement
16-30 VDC, 3 W, Class 2

Current Draw				45 mA @24 VDC (max)

Wiring					LAN Modbus® RTU (version 1.1b3) RS-485, 16 gauge, 4-conductor shielded 
network wiring (daisy-chain)

Fuses					        Thermal, resetting


Environmental
Operating Temperature
-20°C to 40°C (-4°F to 104°F)

Operating Humidity			15 - 90% RH non-condensing


Certifications
Conforms to
CSA-C22.2 No. 205-12 / UL508 (Edition 17):2007 EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010 FCC. This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful