ESH-A Remote Sensor

ESH-A Remote Sensor
For monitoring: Methane, Propane, Hydrogen, TVOCs
Single analog remote sensor for flexible location monitoring
Applications
Parking Facilities, Vehicle Repair Shops, Equipment / Machinery Rooms, Manufacturing Plants, Food Processing
Plants, Battery Charging Rooms and
many more...
Key Features
  • Allows remote location monitoring of combustible gases or TVOCs
  • Current or voltage output signal
  • Communicates with many of CETCI’s controllers and transmitters
  • Easy to to install and maintain
  • Standard water / dust tight, corrosion resistant enclosure (drip proof)
  • IP54 rated with optional splash guard installed

 Description
The ESH-A Remote Sensor offers flexible location monitoring of combustible gases or PID TVOCs in non-hazardous, 
non-explosion rated, commercial and light industrial applications. It communicates with the device it is attached to 
using current loop into a 100 ohm load or a voltage signal of 0.40 to 2 volts. It can be located at a maximum
distance of 200 meters from the compatible controller or transmitter.
The mounting height of the ESH-A Remote Sensor depends on the gas being monitored. A gas that is heavier than 
air should be detected 6 inches from the floor and a gas that is lighter should be detected on or near the ceiling.
A gas that has the same density as air should be detected in the “breathing zone”, where most human breathing
takes place, which is 1 to 2 m (4 to 6 ft) from the floor.
The ESH-A Remote Sensor comes in a standard water / dust tight, corrosion resistant ABS / polycarbonate enclosure 
with a hinged, secure door and is designed to protect the sensor and provide easy mounting components.
An optional splash guard may be installed to further protect the remote sensor in water spray or washdown 
applications.
The ESH-A Remote Sensor is not a standalone device, it must be used with the SCC, DCC, LPT-A, LPT-P, LPT-M, 
LPT-B or CGAS-D (remote sensor's target gas will differ based on device).
 Specifications
Target Gas

Catalytic Sensors
Hydrogen (H2), Methane (CH4), Propane (C3H8), Acetylene (C2H2), Ethanol or
Dimethyl ether (C2H6O)

PID Sensors				        TVOCs

Infrared Sensors				Propane (C3H8)


Mechanical
Enclosure
ABS / Polycarbonate, corrosion resistant Copper coated interior to reduce RF interference IP54 rated with splash guard installed

Weight					181 g / 0.4 lbs

Size					        127 x 127 x 53 mm / 5.0 x 5.0 x 2.1 inches

Input/Output

Output Current loop into a 100 ohm load, or Voltage signal of 0.40 to 2 volts


Electrical
Power Requirement
12 - 24 VDC, 1 W Class 2

Current Draw				45 mA @24 VDC (max)

Wiring					4-conductor 18 AWG stranded, shielded


Environmental
Operating Temperature
-20°C to 40°C (-4°F to 104°F)

Operating Humidity			15 - 90% RH non-condensing


Certifications
Conforms to
CSA-C22.2 No. 205-12 / UL508 (Edition 17):2007 EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010 FCC. This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. RoHS compliant circuit boards

Technical Library   Part Numbers
Visitors: 70,626