cGas Detector for Indoor Public Spaces

cGas Detector for Indoor Public Spaces
For monitoring: Carbon dioxide, Carbon monoxide, Formaldehyde, TVOCs, Particulates, RH & Temperature, Refrigerants
One or two channel gas detector with an aesthetically pleasing design to reduce noticeability when used in publicly 
occupied spaces such as hotels and schools
Applications
Hotels, Office Buildings, Hospitals, Apartment Buildings, Retirement Homes, Theatres / Auditoriums, Schools / 
Universities / Dormitories 
and many more...
Key Features
  • One 4-20 mA analog output or user in the field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485
    digital output signal to a BAS
  • Easy Plug & Play Smart Sensor replacement at end of life
  • Pre-calibrated replacement sensors
  • Bright LCD display
  • Models available with user selectable 1PM, 2.5PM or 10PM particulate sensor
  • Optional 2A SPDT dry contact relay (Option -RLY)
  • Optional RH & Temperature sensor (Option -RHT)
  • Low profile to reduce noticeability in public spaces
  • USB port for configuration changes and firmware upgrades
  • RoHS compliant circuit boards

 Description
This cGas Detector is designed for use in publicly occupied spaces where integrated demand controlled ventilation 
(DCV) is used for air quality and energy savings; for continuous monitoring of refrigerants where high-efficiency,
high volume refrigerant cooling and heating systems (VRF) are used to keep the indoor environment comfortable;
and for other continuous monitoring of hazardous gases in publicly frequented areas. The low profile, aesthetically
pleasing enclosure is designed to reduce the noticeability of the device by the public eye. It is secured by a
mounting plate that can be mounted proud of the wall or flush with the wall using a junction box.
Both the analog and digital models are powered by 24 VDC or ground referenced AC, come with an LCD display, 
temperature compensation and thermalresetting fuse. Sensor replacement is easy with true Plug & Play smart
sensors that arrive pre-calibrated. The firmware and configuration can be upgraded
in the field using the USB connection.
The digital models are user configurable in the field for BACnet® MS-TP RS-485 or Modbus® RTU RS-485 output 
for communicating with a controller, Building Automation System or other control panel.
Both the analog and digital models may be configured with an internal gas sensor or a remote refrigerant sensor 
(dongle). The internal sensor model is ideal for mounting flush with the wall. The remote refrigerant sensor model
has a 9m / 29.5ft dongle cable that is ideal for use in packaged terminal air conditioner (PTAC) applications.
 Specifications
Target Gas

Gas Sensors Carbon dioxide (CO2), Carbon monoxide (CO), Formadehyde (CH2O),
TVOCs, Refrigerants


Target Other

Sensors Particulates (user selectable 1PM, 2.5PM or 10PM) RH & Temperature

Mechanical
Enclosure White ABS / Polycarbonate, low profile with mounting plate

Weight					        400 g / 14 oz

Size					                127.7 x 119 x 40 mm 5.0 x 4.7 x 1.6 in

Dongle Cable Length			        9 m / 29.5 ft (available with the CGAS-AP-RD and CGAS-DP-RD models)


User Interface
Display
2-line by 16 character graphic LCD, Operating Temp: 0°C to 40°C
/ 32°F to 104°F

Push Buttons				        Initiate calibration and menu options with internal UP, DOWN and 
ENTER push buttons

USB Port					        Internal port for USB memory stick for field configuration updates 
/ firmware upgrades

Audible Alarm				        none


Input/Output

Analog Output (CGAS-AP models)		One 4 - 20 mA analog signal used for gas reading

Digital Output (CGAS-DP models)		User configurable in the field, BACnet® MS/TP (version 1 rev 14) RS-485 
or Modbus® RTU (version 1.1b3) RS-485 (user configurable in the field)

RH & Temperature (Option -RHT)*		User selectable units DegC or DegF

Relay (Option -RLY)**			        One SPDT dry contact, rated 30 volts, 2 amps max


Electrical
Power Requirement
16-30 VDC, 3 W, Class 2 12-27 VAC, 50-60 Hz, 3 VA, Class 2

Wiring (analog)				        VDC (or ground referenced AC): 3-conductor 18 AWG (or larger) shielded, 
stranded within conduit VAC 4-conductor shielded 18 AWG stranded within conduit

Wiring (digital)				        VDC or VAC (ground referenced) 4-conductor shielded 16 AWG stranded 
within conduit network wiring (daisy-chain)

Fuse(s)					        Automatic resetting thermal


Environmental

Operating Temperature 0°C to 40°C (32°F to 104°F)

Operating Humidity				15 - 90% RH non-condensing


Certifications

Conforms to
CSA-C22.2 No. 205-12, UL508 (Edition 18):2018
EMC Directive 2014/30/EU, EN 50270:2015, Type 1, EN61010
FCC. This device complies with Part 15 of the FCC Rules.
Listed by BTL

Technical Library   Part Numbers
Visitors: 76,824