MGS-550

MGS-550

Industrial Refrigerant Gas Detector

  • Flexible two-sensor capability, local and/or remote
  • One user-interface platform for all sensor types
  • Two analog outputs and Modbus RTU interface
  • Three fully configurable, user-assignable relays
  • Magnetic wand enables easy, non-intrusive configuration/calibration
  • IP66 ABS or aluminum enclosure options

Description

Bacharach’s advanced MGS-550 gas detector can utilize any combination of sensor technologies, including electrochemical, semiconductor (MOS), catalytic bead or infrared, in a single platform for unparalleled detection capability. The MGS-550 can easily be connected to any central control system using the current and volt analog output or the Modbus RTU interface. With three user assignable relays, it can also function as a stand-alone unit without the need to wire alarm devices back to a central system.

The straightforward menu structure is identical throughout the platform reducing the amount of training required for installing and maintaining this product family. At any point in time, the instrument can be upgraded from a one sensor to a two sensor system by simply registering another sensor. The MGS-550 is furnished with two analog outputs which can be assigned as redundant for one or for transmit the signal of two sensors.

Specifications

 
Type Gas detector using Semiconductor, Electrochemical, Infrared or Catalytic Bead sensor.
For one or two sensor configuration
Gases Toxic gases:
Ammonia, Carbon Dioxide, Carbon Monoxide, Chlorine, Ethylene, Fluorine, Hydrogen Chloride, Hydrogen Cyanide, Hydrogen Sulfide, Nitrogen Dioxide, Ozone, Sulfur Dioxide, VOCs and Oxygen
Combustible gases:
Methane, Propane, Butane, LPG, and Hydrogen
Refrigerants:
Ammonia, Carbon Dioxide, Hydrocarbons, and HFCS, HCFCS, CFCS
Measuring Range
O2 30 Vol%
CO 1,000 ppm
H2S*** 100 ppm
NH3*,*** 100 / 1,000 / 5,000 / 10,000 ppm / 100 %LEL
CO2 5,000 / 10,000 / 20,000 / 30,000 / 40,000 / 50,000 ppm
Refrigerants 1,000 / 10,000 ppm
Combustible Gases 100 %LEL
H2 10,000 ppm
C2H4 2,000 ppm
VOC 1,000 ppm
CI2** 10 ppm
F2** 1 ppm
HCI** 10 ppm
SO2*** 10 ppm
NO2*** 20 ppm
HCN*** 30 ppm
O3** 1 ppm
Display 5-digit, 7-segment red LED and green status LEDs
Output Analog                             4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V
Digital                              Modbus RTU via RS 485
Power Supply 19.5 to 28.5 VDC or 24 VAC ± 20%; 3- or 4-wire
Relay 3 relays, SPDT, user assignable
Rating 1 A @ 24 VDC, 0.25 A @ 240 VAC, resistive load
Alarm delay 0 to 15 minutes; user-programmable
Ambient Conditions Temperature                     - 40 to +120 °F (40 to +50 °C)
Humidity                          5 to 90 %RH, non condensing
Altitude                            0 to 10,000 ft (3,050 m)
Enclosure options Explosion-proof: Powder coated, copper free aluminum, with four M20 x 1.5 ports
General Purpose: IP66 Rated ABS with four M20 x 1.5 ports
Size (w x h x d) General Purpose: 8.3” x 8.9” x 3.4” (210 x 225 x 85 mm)
Explosion-proof: 4.9” x 7.5” x 3.5” (125 x 190 x 90 mm)
Weight General Purpose: 2 lbs (1 kg)
Explosion-proof: 3.5 lbs (1.6 kg)
Approvals CE, UL, CSA, IEC, EN 61010-1
II 2G Ex d IIC Gb; XP enclosure only

 

*Ammonia available as low temperature version -40°F / -40°C (not for 5,000 ppm electrochemical sensor)

**Not IP66 rated; not available for XP enclosure

***Not available for XP enclosure

Visitors: 77,084