The PGM-IR offers superior performance and functionality for low ppm level leak detection of refrigerants, Carbon Dioxide, Nitrous Oxide or Sulfur Hexafluoride. A built-in library of 50 refrigerants enables the PGM-IR to accurately detect the smallest leaks at their source. The unit is immune to sudden changes in temperature or humidity and to over-exposure. The PGM-IR requires no zeroing of positive readings with extended exposure to gas. It has a data logging capacity of up to 200 readings.
With its high flow rate, real-time ppm concentrations or TWA values are displayed instantly with corresponding audible tick-rate indicator to precisely pinpoint leaks. Rapid clearing time enables accurate ambient-air leak detection using the probe along a chiller or display-case. A re-zeroing algorithm and filter/bladder system allows the unit to be used in contaminated areas without affecting target gas readings. The rechargeable Li-ion battery provides a minimum of 8 hours of runtime for all-day usage.
Specifications
Type | Portable Gas Monitor using infrared NDIR sensor |
Gases | Refrigerants CFCs, HFCs, HCFCs, HFOs |
Natural Refrigerant CO2 | |
Medicine and Propellan N2O | |
Inert Gas SF6 | |
Measuring Range | Refrigerants: 0 to 10,000 ppm CO2: 0 to 8,000 ppm N2O, SF6: 0 to 1,000 ppm |
Sensitivity | 1 ppm |
Flow Rate | 1 L/min (typical) |
Response Time | t90 ≤ 5 s |
Display | Backlit graphic LCD; audible ticker |
Battery | Rechargeable Li-Ion, 8 hours of continuous operating time |
Ambient Conditions | Temperature 32 to +122 °F (0 to +50 °C) |
Humidity 5 to 90 %RH, non condensing | |
Altitude 0 to 6,560 ft (2,000 m) | |
Enclosure | Powder coated aluminum in soft case with shoulder strap |
Size (w x h x d) | Approx. 19” x 5” x 8” (500 x 130 x 200 mm) |
Weight | Approx. 7 lbs. (3.2 kg) |
Approvals | CE mark; NOT approved for use in classified, hazardous areas |